12 volts fourRoad remote control switchZL-P4-12SInstruction Manual
◆Applicable scenarios
This product is suitable for remote control motor forward and reverse rotation, barrier gate telescopic doors, electric doors and windows, electric dining tables, display tables, lighting fixtures, security alarms, various industrial signal controls, lifting equipment, etc. It involves various civilian and industrial product fields and has a wide range of usage space.
◆Technical Specifications
1. Working voltage: DC12V
2. Rated current: Resistive load 6A, capacitive and inductive load 4A (please add AC contactor for indirect control when power is too high)
3. Working mode: jog, self-locking, and interlock (selected by dip switch)
4. Output mode: dry contact output or live output
5. Receiving frequency: 433MHz
6. Receiver sensitivity: -105db
7. Size: 28 * 53 * 74mm
◆Matching remote control
This product can be paired with fixed code and learning code remote controls.
The chips of the fixed code remote control include PT2262, PT2264, PT2260, SCT2260, HS2260, etc. Taking PT2262 as an example, the oscillation resistor ranges from 1.8M ohms to 4.7M ohms, with 3.3M ohms being the best.
The chip of the learning code remote control, such as EV1527, has an oscillation resistance of 180K-390K, with 300K being the best.
The remote control has four buttons for regular data bits. Learning one button automatically assigns several more buttons.
◆Instructions for Use:
1. Reset:Press and hold the learning button for a long time, and the learning indicator light will turn on. After 5 seconds, the light will turn off, indicating successful resetting. After resetting, the previously equipped remote control no longer works.Note:If it has already been matched before leaving the factory, do not perform a reset operation!
2. Supporting remote control:Press and hold the learning button, the indicator light will turn on. Release your hand and press any button on the remote control to emit a signal. The indicator light will flash a few times to indicate that the remote control has been learned and matched. If you need multiple remote controls, you can continue to press the remote control. When you no longer need to check the code, you can press the code check button or wait for the indicator light to turn off for 10 seconds to automatically exit the code check state.
3. Work mode selection:The working mode can be selected through the DIP: interlock L, jog M, self-locking T
Taking the control of lighting fixtures as an example, the three working modes are as follows:
Jogging: Press and hold the button, the light will turn on, release the hand light to turn off. (Single key independent control)
Self locking: Press once to turn on the light, press again to turn off the light. (Single key independent control)
Interlock: Press the A key to turn on the A light; Press the B key, the A light will turn off and the B light will turn on. (Mutual constraint, with only one set of lights on)
Note:If it is a fixed code remote control of the same type, simply use the same address code as the already matched remote control, and any number of remote controls can be configured. If you find that someone else's remote control can also control your switch (duplicate code phenomenon), first reset the switch, then replace the remote control with another address code and re match it.
◆Output mode change and wiring diagram
This product defaults to a dry contact output (i.e. a non charged output),Control four sets of switch signals or control the on/off of other power sources:
Input:IN+: for 12V positive input IN -: for 12V negative input
output: NO is a normally open terminal, COM is a common terminal, NC is a normally closed terminal
Under normal circumstances, the COM end is connected to the NC end. After pressing the remote control, the COM end is disconnected from the NC end and connected to the NO end, achieving an on and off function.
It can also be set to output live mode:
Attention: There are five frames at the bottom of the control board, ABCDE. With a soldering iron, you can short-circuit two points inside these five frames to achieve NO control positive wire output, saving the trouble of connecting the green wire in the above picture.